Product Description
|
Cycling Capacity |
|
|
20 hour rate |
64 Amp Hours |
|
Reserve Capacity |
|||
|
@ 25 Amps |
120 minutes |
@ 75 Amps |
21 minutes |
|
Mechanical Specifications |
|
|
Group Size |
25 |
|
Terminal Type |
AP |
|
Total Height |
8.66" (220 mm) |
|
Height |
7.95" (202 mm) |
|
Width |
6.85" (174 mm) |
|
Length |
9.45" (240 mm) |
|
Weight |
49.2 lbs (22.3 kg) |
|
Case Type |
ABS Plastic - Flame Res Rating UL94-HB |
|
Discharge Table (Constant Current) |
||
|
Time |
Amps |
Rate |
|
20 hr |
3.2 |
0.05 CA |
|
10 hr |
5.8 |
0.1 CA |
|
8 hr |
7 |
0.13 CA |
|
5 hr |
10.4 |
0.25 CA |
|
3 hr |
16.5 |
0.33 CA |
|
2 hr |
21.6 |
0.5 CA |
|
1 hr |
36 |
1 CA |
|
Electrical Specifications |
|
|
Nominal Voltage |
12 Volt |
|
Capacity @ 100 hour rate |
70 AH |
|
Capacity @ 20 hour rate |
64 AH |
|
Capacity @ 10 hour rate |
57 AH |
|
Capacity @ 5 hour rate |
51 AH |
|
CCA |
750 |
|
CA or MCA |
900 |
|
Short Circuit Current |
2480 Amps |
|
Internal Resistance |
5m Ω |
|
Charge Voltages |
||||
|
|
Battery Voltages |
|||
|
Charge Stage |
12V |
24V |
36V |
48V |
|
Bulk |
14.7 V |
29.4 V |
44.1 V |
58.8 V |
|
Absorption |
14.7 V |
29.4 V |
44.1 V |
58.8 V |
|
Float |
13.6 V |
27.2 V |
40.8 V |
54.6 V |
|
TC Factor: -4mV/°C/cell |
||||
|
Temperature Range Specifications |
||
|
Condition |
Recommended |
Maximum |
|
Storage |
-15°C to 50°C |
-40°C to 71°C |
|
Operation |
-15°C to 40°C |
-40°C to 71°C |
|
Charge with TC |
-15°C to 50°C |
-40°C to 71°C |
|
Charge without TC |
0°C to 40°C |
-15°C to 50°C |
|
Terminal Torque Specifications |
|||
|
Terminal Type |
ft-lbs |
in-lbs |
Nm |
|
AP | DT (AP) | M6 | M6M (stud) | TP07 (AP) | TP08 (AP) |
4.2 - 6.5 |
50-75 |
5.6 - 7.14 |
|
FR45 |
6.0 - 7.10 |
70-95 |
7.9 - 10.6 |
|
M8 | LT |
7.1 - 8.5 |
85-100 |
9.6 - 10.12 |
|
DT (stud) | M10M (stud) |
9.2 - 10.9 |
110-130 |
12.2 - 14.5 |