Product Description
Cycling Capacity |
|
20 hour rate |
14 Amp Hours |
Reserve Capacity |
|||
@ 25 Amps |
15 minutes |
@ 75 Amps |
0 minutes |
Mechanical Specifications |
|
Group Size |
|
Terminal Type |
M6 |
Total Height |
5.16" (131 mm) |
Height |
5.16" (131 mm) |
Width |
3.39" (86 mm) |
Length |
6.97" (177 mm) |
Weight |
11.0 lbs (5 kg) |
Case Type |
ABS Plastic - Flame Res Rating UL94-HB |
Discharge Table (Constant Current) |
||
Time |
Amps |
Rate |
20 hr |
0.8 |
0.05 CA |
10 hr |
1.4 |
0.1 CA |
8 hr |
1.5 |
0.13 CA |
5 hr |
2.3 |
0.25 CA |
3 hr |
3.4 |
0.33 CA |
2 hr |
4 |
0.5 CA |
1 hr |
8.7 |
1 CA |
Electrical Specifications |
|
Nominal Voltage |
12 Volt |
Capacity @ 100 hour rate |
16 AH |
Capacity @ 20 hour rate |
14 AH |
Capacity @ 10 hour rate |
12 AH |
Capacity @ 5 hour rate |
10 AH |
CCA |
185 |
CA or MCA |
240 |
Short Circuit Current |
600 Amps |
Internal Resistance |
11m Ω |
Charge Voltages |
||||
|
Battery Voltages |
|||
Charge Stage |
12V |
24V |
36V |
48V |
Bulk |
14.7 V |
29.4 V |
44.1 V |
58.8 V |
Absorption |
14.7 V |
29.4 V |
44.1 V |
58.8 V |
Float |
13.6 V |
27.2 V |
40.8 V |
54.6 V |
TC Factor: -4mV/°C/cell |
Temperature Range Specifications |
||
Condition |
Recommended |
Maximum |
Storage |
-15°C to 50°C |
-40°C to 71°C |
Operation |
-15°C to 40°C |
-40°C to 71°C |
Charge with TC |
-15°C to 50°C |
-40°C to 71°C |
Charge without TC |
0°C to 40°C |
-15°C to 50°C |
Terminal Torque Specifications |
|||
Terminal Type |
ft-lbs |
in-lbs |
Nm |
AP | DT (AP) | M6 | M6M (stud) | TP07 (AP) | TP08 (AP) |
4.2 - 6.0 |
50-70 |
5.6 - 7.9 |
FR45 |
6.0 - 7.5 |
70-90 |
7.9 - 10.1 |
M8 | LT |
7.1 - 8.0 |
85-95 |
9.6 - 10.7 |
DT (stud) | M10M (stud) |
9.2 - 10.4 |
110-125 |
12.2 - 14.0 |